UNI-T UT586+ Digital RCD Tester
R9,999.00
The UT586+ is an instrument crafted for verifying the functionality of single-phase and three-phase electrical leakage protection devices. It is equipped with capabilities to measure fault triggering times and the currents that initiate tripping. Adhering to the CAT III 600V safety rating, it finds broad application across residential, educational, power, manufacturing, metallurgical, and chemical sectors.
FEATURES:
Certifications: CE/RoHS
1. RCD trip time/Current test
2. Multiple range & Auto range
3. Phase angle selection
4. Working voltage: 100V~440V
5. Voltage test: 30~480V
6. Over temp. detection
7. Backlight & APO & Low battery
8. CAT III 600V
Specification
Fault trigger timeAccuracy
(current)Accuracy
(time)
RCD test function
X1/2
-Rate trigger current: 10/20/30/100/300/500mA/1000mA
-Fault trigger time: 0~2000mS @ 0 /180
X1
-Rate trigger current: 10/20/30/100/300mA
-Fault trigger time: 0~2000mS @ 0 /180
-Rate trigger current: 500mA/1000mA
-Fault trigger time: 0~200mS @ 0 /180
X2
-Rate trigger current: 10/20/30/100/200/300/500mA
-Fault trigger time: 0~200mS @ 0 /180
X5
-Rate trigger current: 10/20/30/100/200mA
-Fault trigger time: 0~200mS @ 0 /180
AUTO
-Rate trigger current: 10/20/30/100/300/500mA/1000mA
-Fault trigger time:300ms @ 15 0 /180
MANUAL
-Rate trigger current: 10/20/30/100/300/500mA/1000mA
-Fault trigger time:300ms @ 0 /180
Working voltage
-50/60Hz100V~440V
(Note: If > 450V, it will issue an alarm and stop the RCD test)-15%~+10%
Voltage test
-Voltage range30~480V (Resolution: 1V)45~65Hz
Voltage test
-L-PE yes, display the L-PE input voltage;
range: 30V~480V; No input and low voltage: "0V";
if less than 30V: 480V
- Frequency yes, display the L-PE input frequency;
when it is "volts", press "VOLT/FREQ" key to switch "Voltage/Frequency"
-Wiring check If there is no wiring, an abnormal power supply, or no electricity flowing, the LCD will display "L-PE" and flash.
-Phase angle selectionYou can choose to initiate the test from the positive (0 ) or the negative (180 ) half-cycle. Press the "0 /180 " button to toggle phase.
-Lock test With the power disconnected, press and hold the "0 /180 " button to activate the lock test function. Simply connect the test leads correctly to the test points, and the test will run automatically.
-AUTO RAMP testYou can test the trip action current and action time simultaneously.
-RCD test exceeds limit prompt When the trip action time exceeds the maximum test duration and trips.
-Over-temperature detection If the internal components of the device become too hot, the LCD will display an over-temperature symbol, and the device will automatically disable RCD testing.
-BacklightYes, can be turn on/off
-Low battery indication yes
-Auto power offAfter 5 minutes of no operation, it will automatically shut down.
-Working environment0 ~40
-Storage environment -20 ~60
-Power8 x 1.5V
AAPolution level2
Safety ratingIEC61010-031; IEC61557-1,6; CAT III 600V
Disclaimer - This product is genuine and sourced from the authorised South African importer.
Seller is an independent reseller and is not affiliated with or endorsed by any third party claiming trademark rights.
What's in the box
1 x Tester
1 x Manual
1 x Set Test Leads
1 x Set Alligator Clips
1 x Set Test Probes
8 x Batteries
Additional information
| Weight | 0.00 kg |
|---|---|
| Dimensions | 0.00 × 0.00 × 0.00 cm |

Reviews
There are no reviews yet.